Kyoritsu KEW 3124A - High Voltage Insulation Tester
✅ Permits a wide range of insulation testing up to 100GΩ at variable test voltage from 1kV to 10kV
✅ Output voltage is shown on the digital display | DC voltage output for recorders
✅ After tests, automatically discharges the charges stored in the circuit under test
✅ Live voltage warning
✅ Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V
Hotline: 0911.159.019
Email: sales@thietbidochuyendung.com
High Voltage Insulation Tester
Kyoritsu KEW 3124A
✓ Suited for heavy duty electrical maintenance and servicing of industrial installations, cables, transformers, generators and switch gears where high voltage insulation tests are required
☑ Measures high voltage insulation resistance up to 100G at a variable voltage between 1kV and 10kV.
☑ The digital display indicates set voltage at 100G and output voltage.
☑ After a test, it also shows remaining charges stored in the circuit or equipment under test.
☑ Easy-to-read auto-ranging dual scales for 100G 2 range that are color coded for high and low resistance ranges.
☑ The LEDs illuminate in matching color to indicate which range is operative.
☑ After tests, automatically discharges the charges stored in the circuit under test.
☑ Completion of discharging can be checked by voltage readings on the digital display.
☑ Output terminal to provide DC voltage in proportion to the test voltage and test current for connection to such equipment as a chart recorder.
☑ Operated by Ni-MH (Nickel metal hydride) batteries which can be charged from AC power source or 12V DC car battery. During insulation tests, the buzzer warns presence of high voltage.
☑ Battery Alarm warns by alternating its color, when battery voltage lowers.
☑ Battery Charging Indicator shows completion of battery charging by alternating its color.
✍Spectification
Technical Data
Test voltage |
1000V |
1000V - 10kV (variable in 10V increments) |
|
Measuring ranges (Automatic change) |
100MΩ [1000V] |
1.6GΩ/100GΩ (auto ranging) [1000V - 10kV] |
|
Measurement accuracy |
±10% rdg |
Other ranges accuracy |
±1% of scale length (with measurement voltage less than 2kV, 0 to 100GΩ is not guaranteed accuracy) |
Open circuit voltage |
±10% [1000V] |
±2% [1000V - 10kV] |
|
Output voltage and set voltage indicate |
DC 0-10kV ±2%rdg±2dgt |
Power source |
Ni-MH (1.2V) ×8 / External supply DC 15V |
⏬ Download
📑 Datasheet | 📒 Instruction Manual | 💽 Software | USB Driver
💫Brochure