Yokogawa CA500 - Multi Function Process Calibrator
Multi Fuction
The CA500 and CA550, are the new high-performance and multi-function calibrators from Yokogawa. These newer models offer useful functions for field work and provide improved source and measurement accuracy, sufficient for calibrating field instruments with higher accuracy and confidence.Thay thế các dòng 150
|
.
Calibration work
Easy-to-view Display
Thermocouple generation using TC Mini Plug
UP/DOWN keys
|
Wiring information display function
Easy-to-use key operation
Operation key layout
|
---|
.
Application
Yokogawa CA550 | CA500
20 mA SIMULATE The CA500 series can be used as a transmitter simulator to perform a loop test. It sinks the set current from an external voltage source of instrumentation equipment. Zero point adjustment of HART transmitter
CA550 supports HART communication (Universal command/Common practice command). Reading of HART device information, writing of LRV/URV, and trimming of analog output are possible. RTD SIMULATE CA500/CA550 corresponds to 14 types of RTD for sourcing.It achieves the high basic accuracy of 0.1°C* (typical of type Pt100), which enables it to operate a highly reliable test. Additionally, input and output testing of temperature transmitters is possible at the same time. *Accuracy for CA550
The following items are supported by HART communication function
|
Two-wire Transmitter Loop Check DC mA signals can be measured by supplying power to the transmitter from a 24 V DC power supply. DC mA signal measurement and zero-point check can be performed with an accuracy of 0.01% of reading (0.015% of reading for CA500).
TC SIMULATE The CA500 series corresponds to 17 types of TC for sourcing. It achieves the high basic accuracy of 0.5°C (typical of type K), two times better than the previous model. Also, input/output testing is possible with a single CA500/CA550, as it can measure output signals.
Pulse SIMULATE This calibrator performs measurement of pulse signal integration from a flowmeter and generates a pulse to a receiver, such as integrating counter or pulse converter. Integration time can be set from 1 min to 60 min
Automatic input/output testing (Program sweep)Automatic input/output testing is possible by setting source values for each step for a calibration target. Calibration results such as generated value, measured value, error rate, date/time, and pass/fail are saved in CSV format in the CA550 main unit. By connecting the CA550 to a PC using a standard USB cable, the instrument can be recognized as a massstorage device for data to be transferred to the PC. |
---|
.