Yokogawa DL850E / DL850EV - Thiết bị ghi tín hiệu sóng
Please call us ! 📞
DL850E combines a mixed signal oscilloscope and portable data acquisition recorder
Modular platform designed to capture both high-speed transients and low speed trends
Combining signal conditioning, signal processing, and large recording memory
DL850E is ready to be configured to meet your application demands.
With its menu-driven user interface, advanced features are easily accessible, so you can gain insights and solve problems faster.
Hotline: 0911.159.019
Email: sales@thietbidochuyendung.com
DL850E/DL850EV ScopeCorder
Product Overview
Most processing options
Deepest memory
| Highest channel count
|
Technical
Flexible and modular inputs with built-in signal conditioning
Input modules lineup for DL850E and DL850EV
Voltage
Voltage100 MS/s 720211 | Voltage 10 MS/s 720250 | Voltage 1 MS/s, 2-CH input 701251 | Voltage 1 MS/s, 4-CH input 720254 | Voltage 10 MS/s, Non-isolated 701255 | Voltage 1 MS/s, High voltage 720268 | Voltage 200 kS/s, 16-CH input 720220
Voltage , Temperature
Voltage, Temperature 100 kS/s 701261 | Voltage, Temperature 100 kS/s, with AAF 701262 | Voltage, Temperature High sensitivity 701265 | Voltage,Temperature High sensitivity, Low noise 720266 | Voltage, Temperature (scan method) 720221
Strain, Acceleration, Frequency, Logic, CAN/CAN
Strain NDIS 701270 | Strain DSUB 701271 | Acceleration, Voltage 701275 | Frequency 720281 | Logic 720230 | CAN/CAN FD 720242 | CAN, LIN 720241 | SENT 720243
General
Display | 10.4-inch TFT color LCD monitor, 1024×768 (XGA) Max. 3 simultaneous displays available In addition to main, 2 more available among zoom 1, zoom 2, XY1, XY2, FFT1, FFT2 (/G2 option), Vector (/G5 option), Bar graph (/G5 option) |
Power supply | 100-240VAC (50/60 Hz) |
Maximum power consumption | 200VA |
Withstand voltage | 1500 V AC between power supply and earth for 1 minute |
12 V DC power (/DC option, for DL850EV only) | Automatic DC/AC switching (with priority on AC), isolated between DC power input terminal and main unit |
---|---|
Storage | Memory cards conforms to SD, SDHC, USB memory, External HDD (/HD0 option), Built-in HDD (/HD1 option) |
USB interface | USB peripheral interface, USB peripheral interface |
Ethernet | Connector type RJ-45 modular jack ×1 |
Function
Real-Time Measurement of Electrical Power - /G5 option
Get results faster with real-time signal processing for electrical power parameters. Trend calculations such as active power, power factor, integrated power and harmonics, using a dedicated Digital Signal Processor (DSP) that is able to calculate and display up to 126-types of electrical power related parameters in real-time. This enables the user to display raw waveform signals such as voltages and currents along with power calculated parameters and even the capability to trigger on all of them. Data updating rate up to 100kS/s. Trend waveforms of each order of harmonics, bar-graphs and vector displays can be displayed. Both RMS and Power analysis modes are available. Besides the powerful power calculations, the /G5 option also contains all the functionality of the /G3 real-time math option.
Gapless Real-Time Calculations
Taking advantage of the real-time calculations of power parameters allows engineers to create a high-channel count, time series data set of mixed signals including sensors, automotive serial bus data, and accessory analog and discrete inputs. This is ideal for such scenarios as:
- Long-term monitoring or validation of power system performance over hours or days of testing
- Fast transient evaluation while operating test vectors such as start-up, emergency shutdown, or vehicle simulated drive conditions
- Using enhanced triggers to evaluate power parameters and trap unusual behavior for continuous improvement
DL850EV Vehicle Edition
ScopeCorder Vehicle Edition is designed for engineers working in the automotive and railway industry, providing a thorough insight into the dynamic behavior of the electromechanical system. This integrated approach results in considerable time saving compared to using multiple separate instruments.
CAN/CAN FD or LIN/SENT bus Monitoring
Use a ScopeCorder to decode the CAN/CAN FD or LIN bus or SENT signals and display information on physical data like engine temperature, vehicle speed and brake-pedal position as analog waveforms and compare this with the data coming from real sensors
Powerful Real-Time Calculations and Analysis Functions
As a standard feature, the ScopeCorder is equipped with a set of basic arithmetic functions such as addition, subtraction, division, multiplication, Fast Fourier transformation and more. In addition to standard math, advanced real-time analysis functions are available.
Real-Time Mathematical Computations and Digital Filtering - /G3 option
Armed with a dedicated digital signal processor the ScopeCorder can perform mathematical calculations such as arithmetic operators with coefficients, integrals differentials, and higher order equations on acquired measurement data. The results of these calculations are displayed during waveform capture in real-time. In addition to mathematical operators, steep digital filters can also be selected to isolate or trigger on the amplitude of certain frequency components.
Measuring the electrical angle corresponding to the mechanical angle is important for understanding motor characteristics. The Electrical Angle operation enables the extraction of the fundamental component of current by Discrete Fourier Transform, then the calculation of the phase difference between it and the rotary angle in real-time. A trend of the phase difference can also be displayed in real-time.