Yokogawa CA71 - Multifunction Calibrator
Please call us ! 📞
Source and measure operations can be performed at the same time
Select from the following source signal and measurement signal
Voltage #current #resistance #thermocouple (T/C)
Resistance temperature detector (RTD), frequency, pulse
AC voltages including supply voltage can be measured
Easy operation
Compact size and Lightweight
Hotline: 0911.159.019
Email: sales@thietbidochuyendung.com
YOKOGAWA CA71
The CA51/CA71 HANDY CAL calibrators are comprehensive generating/measuring instruments for all your calibration and equipment checking needs at maintenance sites. The CA51/CA71 can simultaneously generate and measure voltage, current, TC, RTD and pulse signals, thus you don’t need to prepare many instruments. In addition, the incorporated rotary switches of good repute enable operations so smooth that an incorrect measurement caused from erroneous operations can be prevented
Feature
- Simultaneous signal source and measurement capability: The CA71 lets you handle regular tests on TCs, RTDs and various other types of sensors and instruments, as well as operation checks when a problem has occurred. By itself it can generate signals for input to equipment, and check output signal from equipment. (TC and RTD measurement functions: CA71 only)
- AC voltage (including supply voltage) measurement capability: In cases where numerous signal converters and other devices are mounted on a rack or panel, the CA51/CA71 can be used to check the input and output signals of each device, while simultaneously checking the power supply. There is no need for a separate multimeter to measure supply voltage.
- A wide array of useful functions: Divided output (n/m) function, Auto-step function, Sweep function, Memory function and Communication function are available. (Communication function: CA71 only).
- Easy Operation: The CA51/CA71 incorporates rotary switches for simple handling. Just open the cover of carrying case and connect the cables, and you are ready to take measurement.
FUNCTIONS
| Generation and Measurement of Voltage/Current | | 4−20 mA Step Function |
The CA51/CA71 can generate voltage/current up to 30 V DC/24 mA DC and measure up to 100 V DC/100 mA DC. | You can set the signal in 4 mA increments or decrements in order 4 ⇔ 8 ⇔ 12 ⇔ 16 ⇔ 20 mA by one touch operation |
| 20 mA SINK Function | | Equivalent Output of TC/RTD |
The 20 mA SINK function can draw current from an external voltage source to the H terminal of SOURSE unit. Thus, the CA51/CA71 can be used in a loop test, for example, as a simulator for transmitters | In addition to10 types of TC (K, E, J, T, N, L, U, R, S and B), RTD (Pt100, JPt100) outputs are available. The CA51/CA71 can be used for maintenance of industrial instruments for process or various thermometers. |
| Multi Temperature | | Built-in Reference Junction Compensation Sensor |
The CA51/CA71 can be used as multi thermometer because the measurements for all ranges are available. For RTD, 3-wire measurement is available. | As a means of easily providing reference junction compensation when TC is generated, you can use the temperature sensor within the CA51/CA71. For more accurate reference junction compensation, use RJ sensor (model: B9108WA) sold separately. |